Multiperiod market

market.solve_multiperiod clears a whole horizon — up to and beyond a 24-hour day — as one coupled LP/QP. Every wave before this one solved a single instant: each solve was independent and correctness was checkable one snapshot at a time. Multiperiod clearing introduces temporal coupling: a ramp row ties period t to t-1, a state-of-charge row ties the whole horizon into one energy budget, and a cyclic row closes it. The periods cannot be solved one at a time and then stacked; the coupling rows are what make the answer different from 24 independent clearings.

Entry point Returns
market.solve_multiperiod(scenario, options=None) MarketMultiperiodResult

Runnable script: 10_multiperiod_market.py.

It is built on the same opf.dc_opf row families the nodal clearing uses, through the array-level builder opf.multiperiod_dc_opf — not on a second solver. opf.lmp_decomposition (M3) and opf.gen_cost_coeffs are called verbatim, per period; market.nodal.load_bid_coeffs supplies the load bids, shared rather than copied.

The horizon: Scenario.periods and Period

Scenario gained one field:

Scenario(network: Network, periods: list[Period] | None = None)
Period(load_p_mw: dict[str, float])

Period.load_p_mw is an id-keyed override of each Load.p_mw for that period, not a scale factor: a load id absent from the dict keeps its own Load.p_mw in that period, so a scenario that varies two loads out of eleven names two. Every key must resolve to a real Load id in the scenario's network — checked by Scenario's own validator rather than by Period, since a bare Period has no network to check against.

The values carry exactly Load.p_mw's own range, negatives included, deliberately: an override may not be narrower than the field it overrides. Load.p_mw has no lower bound and case300 ships eight negative loads (a net injection at a load bus), so a >= 0 rule here would reject even the identity profile {ld.id: ld.p_mw for ld in case300.loads} — a horizon that changes nothing — on a network market.solve_nodal clears without complaint. Non-finite values are still rejected.

On a load carrying a bid, Load.p_mw is that load's maximum served quantity, so an override moves the upper bound of its elastic column as well as the fixed-load term — one field, both meanings, both moved. The bid curve is horizon-invariant (per-period bids are out of scope this wave), so a period override rescales how much of that curve is reachable, not its shape.

One edge follows from that, and it is the one place the two ranges above meet. A negative override on a bid-carrying load gives its elastic column the empty bound [0, negative], and the clearing comes back Infeasible. That is neither new nor a multiperiod quirk: dc_opf has done exactly this for a negative Load.p_mw with a bid since M4, and market.solve_nodal reaches it by the same route. A negative load with no bid clears normally at both entry points — on a 2-bus case with a 100 MW fixed load beside it, a -20 MW load solves Optimal at 80 MW of generation whether it is reached as Load.p_mw or as a period override, and turns Infeasible only once a bid is attached to it. Consistent, therefore, rather than a regression — and carried to a later wave rather than changed here.

periods=None means single-period. That is not a special case in the solver; it is the degenerate end of the same code path, and it reproduces market.solve_nodal bit-for-bit (see Degeneracy, below).

Only load quantity varies by period. Cost curves, bid curves, generator bounds, ratings and the network's topology are horizon-invariant. Per-period offers and bids are deliberately out of scope this wave — Period is shaped so a later wave can widen it additively rather than re-cut it. The PTDF matrix is computed once and reused for every period, which assumes a static topology over the horizon: no intra-horizon switching, no mid-day outage.

One builder, not two

opf/multiperiod.py does not reimplement the nodal-balance row, the PTDF flow-limit rows or the piecewise-linear epigraph and hypograph rows. It calls dc_opf's own four internal helpers for them, once per period, against that period's own column indices — the extraction that made this literally true was landed and proved behaviour-preserving before any multiperiod row existed. What is new is the three coupling families a single-period solve cannot have: ramp, SoC, and the cyclic end-of-horizon row.

Column layout — two tiers

The variable vector is not T self-contained per-period blocks. dc_opf passes its quadratic cost Hessian once, over a prefix of the columns, before any free cost_g / val_d PWL variable exists, so the free variables are hoisted into a second tier:

  • tier 1, T * (n_gen + n_demand + 3*n_storage) columns, period-major, each period's block being [gen | demand | charge | discharge | soc]. The Hessian covers exactly this tier.
  • tier 2, T * (n_pwl + n_demand_pwl) columns, period-major, each period's block being [cost_g | val_d].

At T == 1 with no storage this is column-for-column, row-for-row and call-for-call the model dc_opf itself builds — which is what makes the degenerate case exact rather than merely close.

Row families and their order

Row indices are read back for duals, so the order is a contract of this module's own — it is re-derived for T periods rather than inherited from dc_opf:

Tier Family Row index
1 nodal balance, one per period t
2 PTDF flow limit, per branch per period T + t*n_branch + k
3 SoC balance, per unit per period T*(1 + n_branch) + t*n_storage + s
4 charge + discharge <= p_max after tier 3, t*n_storage + s
5 cyclic soc[T-1] == soc_initial after tier 4, s
6 ramp coupling, per ramped generator per adjacent pair after tier 5, (t-1)*n_ramped + j
7-8 PWL epigraph / hypograph rows last — an encoding detail, never part of the dual shape

Ramp coupling

Generator gained two optional fields:

Generator(..., ramp_up_mw: float | None = None, ramp_down_mw: float | None = None)

Both are in MW per period, mirroring Branch.rating_mva's established float | None pattern rather than PyPSA's per-unit-of-p_nom convention — every other physical field on Generator is already physical. None means unconstrained, and a generator with neither limit set gets no ramp row at all, not a row with a large finite bound. A generator with only one of the two set gets a genuinely unbounded side.

A ramp limit of exactly 0 is rejected, and earlier than the solve: Network itself refuses it, with a NetworkValidationError carrying a BAD_RANGE issue, so a zero limit never reaches solve_multiperiod at all. Zero would mean "frozen for the whole horizon", which is never what a caller means; it is MATPOWER's unpopulated ramp-column value, and no bundled fixture populates a ramp column at all. None is the honest default for that data, not 0.

One two-sided row is built per ramp-limited generator per adjacent period pair t = 1..T-1:

\[ -\text{ramp_down_mw}_g \;\le\; p_g[t] - p_g[t-1] \;\le\; \text{ramp_up_mw}_g . \]

GenPeriodDispatchResult.ramp_dual reports that row's shadow price under HiGHS's own row-dual sign convention — negative when the ramp-up side binds, positive when the ramp-down side does, the same convention flow_limit duals already carry. Period 0 has no row reaching into it and reports 0.0 rather than borrowing another period's, and so does any generator with no ramp row at all.

A negative energy price is legitimate here

MultiperiodDuals.balance may be negative in a ramp-constrained period, and correctly so: an extra MW of load in a period a ramp row binds out of can let a cheap unit start climbing earlier and displace an expensive one later. The builder's own hand-derived acceptance case constructs exactly that.

Storage

model.Storage has been in the schema since M1 and solver-ignored ever since. This is the wave that reads it. A network with no Storage builds no storage column and no SoC row, so the formulation costs a storage-free caller nothing.

Two columns, not one signed column

Each unit gets two nonnegative power columns per period, charge and discharge, each bounded [0, p_max_mw], plus an explicit soc column bounded [0, energy_mwh]. Not one signed column: the charge and discharge efficiencies enter the SoC row with different coefficients (+eta_c against -1/eta_d), an asymmetry a single signed column cannot express in one linear row.

The two columns share one row per unit per period:

\[ \text{charge}[t] + \text{discharge}[t] \;\le\; \text{p_max_mw} , \]

so the unit's combined converter throughput is capped whichever way it is running.

SoC balance, with efficiency

\[ \text{soc}[t] - \text{soc}[t-1] - \eta_c\,\text{charge}[t] + \frac{\text{discharge}[t]}{\eta_d} = 0 , \]

one equality row per unit per period, anchored at t = 0 to the unit's own initial energy soc_initial * energy_mwh. StorageDispatchResult.soc_mwh is the state of charge at the end of the period.

soc_dual is that row's shadow price, and it carries HiGHS's own row-dual sign — the same convention flow_limit and ramp_dual already use on this page. It is the negative of the marginal value of stored energy, so it reads negative wherever one more MWh in the unit is worth having: -LMP / eta_c where the unit is charging on an interior column, -eta_d · LMP where it is discharging on one. On the 2-period example at the bottom of this page that is exactly -10 / 0.9 = -11.111 at t=0 and -0.9 × 50 = -45.0 at t=1. Read the worth of an MWh as -soc_dual.

energy_bound_dual is the reduced cost of the soc column's own [0, energy_mwh] bound, and it is non-zero at either end: a unit sitting empty binds that bound exactly as much as one sitting full. It is 0 only where the state of charge is strictly between the two.

Cyclic end of horizon

\[ \text{soc}[T-1] = \text{soc_initial} \times \text{energy_mwh} , \]

one equality row per unit, met exactly rather than to a tolerance. This is not configurable. A free end state or a fixed target would be a third code path this wave deliberately does not ship; a later wave that needs one adds it as an option, not as a second solver. MultiperiodDuals.cyclic reports what the condition itself costs, separably from the SoC dynamics above it.

Simultaneous charge and discharge is bounded, not banned

Because charge and discharge are separate nonnegative columns, an LP solution in which both are non-zero at once is representable. That is deliberate. Banning the overlap needs a binary, which would change the solver class from LP/QP to MILP — and it is not merely an optimality curiosity to be tidied away: there are networks on which forbidding the overlap makes the LP infeasible, and the wave's own research constructed one. So the formulation caps the sum with the shared power-limit row and leaves the overlap representable.

Whether it actually happens on real data is then a measurement, not an assumption: min(charge, discharge) ≈ 0 on every fixture this package ships is a committed invariant test, paired with the constructed network where the same readback is genuinely non-zero — so the near-zero reading is a measurement rather than an absence.

Storage is costless in the objective: model.Storage carries no cost field, so a unit's only economic footprint is the round-trip loss it imposes on generation. Its profit is a settlement outcome, not an objective term.

Per-period LMPs

opf.lmp_decomposition is called once per period, unmodified, with that period's own balance and flow-limit dual slice against the single PTDF matrix the builder already returned:

\[ \text{lmp}_b[t] = \underbrace{\lambda_\text{balance}[t]}_{\text{energy}} + \underbrace{\sum_k \mu_k[t] \cdot \text{PTDF}[k, b]}_{\text{congestion}} . \]

See DC-OPF › Duals and locational marginal prices for the derivation. Nothing about it changes with a horizon in the picture; the duals it consumes already account for the coupling rows.

Every figure on MarketPeriodResult is that period's own, never a horizon average. The $/h quantities are that period's rate, and the horizon totals on MarketMultiperiodResult are their plain sum — an energy-weighted total only because every period is one hour long. There is no period-duration field this wave.

Settlement

MarketPeriodResult reports five settlement figures, each computed directly from that period's own prices and quantities:

  • total_load_paymentΣ_d LMP(bus_d) · p_d over every load, bid or not.
  • total_generator_receiptsΣ_g LMP(bus_g) · p_g over every generator.
  • total_storage_charge_paymentΣ_s LMP(bus_s) · charge_mw, what storage pays for what it stores.
  • total_storage_discharge_revenueΣ_s LMP(bus_s) · discharge_mw, what the market pays storage for what it returns.
  • congestion_rent(load payment + storage charge payment) - (generator receipts + storage discharge revenue).

Storage is a third settlement participant

A storage unit both withdraws and injects at a bus, so it settles on both sides. The identity does not close if a dispatched unit is left unsettled — it is then wrong by exactly the unit's net revenue, which is the whole of its arbitrage profit. The 24-hour example makes this visible directly: on an hour with no binding rating every LMP is equal, so the surplus must be zero, and across that horizon's 17 uncongested hours the largest one the example finds is 2.6e-10 $/h — zero to the LP solver's own precision, not merely small. At hour 4 the load pays 6305.178 $/h, the generators receive 6999.710 $/h, and it is storage's 694.532 $/h charge payment that closes the gap. Drop the two storage columns and the same subtraction reads −694.532 instead of zero.

The identity, in its general form

\[ \underbrace{\sum_d \text{LMP}_d\, p_d + \sum_s \text{LMP}_s\, c_s}_{\text{paid in}} \;-\; \underbrace{\left(\sum_g \text{LMP}_g\, p_g + \sum_s \text{LMP}_s\, d_s\right)}_{\text{paid out}} = -\sum_k \mu_k f_k + \sum_k \mu_k \,\text{pf_shift}_k - \sum_n \text{LMP}_n\, g_{\text{shunt},n} \]

holds per period, at the optimum. The two trailing terms are corrections for phase-shifting transformers and for bus shunt conductance — both fixed, unsettled withdrawals from the network itself rather than from a market participant. They are exactly zero on every MATPOWER fixture this package ships except case300, whose g_shunt is non-zero (max 0.0014 pu, measured).

congestion_rent is the merchandising surplus

The field is the market operator's merchandising surplus, computed directly from prices and quantities. It equals congestion rent proper — exactly -Σ_k(μ_k · f_k) — only on a network with no bus shunt conductance and no phase-shifting transformer. Where either exists, the surplus also carries that unsettled withdrawal. The value is right either way; it is the name that is narrower than the number. The nodal page states the identity in the narrower form, which was correct for the fixtures M4 itself carried.

The identity is proved per period in tests/unit/test_market_multiperiod.py with the right-hand side computed by a separate code path — a second, array-level solve and a recomputed PTDF — so the assertion is a proof rather than a restatement of arithmetic already performed. Note that MarketMultiperiodResult carries no branch rows, so its flow duals μ_k are not reachable from the result object itself; a caller who wants to check the right-hand side has to go to opf.multiperiod_dc_opf for them.

Degeneracy: one period is the nodal clearing

A Scenario with periods=None clears T = 1 from the network's own loads and reproduces market.solve_nodal exactly — the same dispatch, the same duals, the same LMPs, asserted with == and not with a tolerance. That holds on every fixture this package ships, case300 included, with elastic bids in play or without them.

This is not a special case in the code. solve_multiperiod passes period_load_mw=None rather than materialising a copy of the network's own loads, which makes the builder evaluate dc_opf's literal fixed-load and flow-constant expressions; combined with the column layout above, at T=1 the two builders issue identical calls in identical order, so the floating-point arithmetic is the same arithmetic. This is the wave's own agreement test for the shared row-family core: it is what fails if the extraction and the T-loop ever disagree.

An explicit single Period is the weaker claim, and deliberately stated as such. Naming the loads sends the builder down its period_load_mw path instead — the same rows, assembled by array arithmetic rather than by dc_opf's literal expressions — which reorders a handful of floating-point operations. It agrees bit-for-bit on the fixtures the tests assert it over; it agrees to floating-point tolerance, not to the last bit, in general. Measured on rated_network: case57 diverges by 1.7e-13 $/MWh on LMP, case118 by 2.1e-12 $/MWh on LMP, 7.3e-12 MW on dispatch and 2.6e-10 $/h on total load payment. Deterministic, and far below any tolerance a caller should be reading these numbers at — but not ==.

market.solve_nodal ignores Scenario.periods entirely — it is a single-period entry point and stays one.

Errors

market.NonConvexCostError / market.NonConcaveBidError are raised before any solve, exactly as for the nodal clearing. A ramp limit of exactly zero never gets as far as solve_multiperiod: Network rejects it at construction with a NetworkValidationError (BAD_RANGE), which subclasses Exception, not ValueError — see Validation — so a caller writing except ValueError: around the constructor or the clearing catches nothing. (The array-level opf.multiperiod_dc_opf, which takes ramp limits as bare arrays with no Network behind them to have validated first, does raise ValueError for a zero entry.) solve_multiperiod never raises for an infeasible or unbounded LP/QP — that is reported through MarketMultiperiodResult.status / message, mirroring solve_nodal's and opf.solve_dc_opf's never-raise convention. The scenario is not modified.

An infeasible horizon is a real possibility that a single-period clearing does not have: a profile whose per-bus injection pattern departs from the one a network's ratings were derived against can be infeasible over the horizon even where every individual period would solve, and the coupling rows are what make it so.

Oracle & fixtures

No MATPOWER fixture carries multi-period data, storage, ramp limits or real branch ratings — the format has no section for the first two and uses 0 as "unpopulated" for the others. All four are derived at test time from data the fixtures already own, committing no new fixture files, the same discipline tests/_bids.py and tests/_rated.py established for the nodal wave:

  • tests/_periods.py — a 24-hour raised-cosine profile, TROUGH_MULTIPLE = 0.7 at hour 4 up to PEAK_MULTIPLE = 1.2 twelve hours later, applied as a single system-wide curve. An earlier design used two phase-shifted archetypes for locational diversity and had to be abandoned: measured on case14, any per-load divergence from the network's own base-case load ratios — even a 2-hour phase shift at unchanged amplitude — makes the 24-period LP genuinely infeasible, because several of the derived ratings sit at exactly their 20% headroom with no redispatch slack. A single curve keeps every branch's flow proportional to one multiplier, which is what keeps the whole horizon simultaneously feasible.
  • tests/_storage.py — one unit sized at 15% of the network's own total base-case load with a 4-hour duration (38.85 MW / 155.4 MWh on case14), soc_initial = 0.5 so the cyclic condition forbids neither direction in period 0, and deliberately asymmetric efficiencies (0.92 / 0.88, round-trip 0.8096) — an equal pair is exactly the shape under which transposing the two efficiencies in the SoC row is a silent no-op.
  • tests/_rated.py — reused unchanged, at 20% headroom over the base-case flow, so congestion binds in some hours and not others.

The oracle is PyPSA multi-period optimize with StorageUnit and ramp_limit_up/ramp_limit_down, on a 24-period rated case14 with the lossy unit and an asymmetric generator ramp limit (10 MW/h up, 14.5 MW/h down) both genuinely engaged. Measured worst-case residuals, with the pinned tolerances in brackets: objective 4.35e-13 relative (1e-9), per-generator per-period dispatch 3.01e-4 MW (1e-2), net storage power 1.10e-4 MW (1e-2), state of charge 1.25e-4 MWh (1e-2), per-bus per-period LMP 4.24e-5 $/MWh (1e-3).

Two disclosed limits of that oracle

PyPSA's transformer ratings. Rating both the 17 Line and the 3 Transformer components of case14 simultaneously makes PyPSA's constrained QP genuinely infeasible — reproduced from the bare single-period base case up through 3x uniform slack on every rating, so it is not a numerical near-miss. Root cause is unverified beyond "reproducibly fails". The parity test routes around it by rating only the 17 lines in the oracle while this package's engine rates all 20, and asserts that every branch which actually binds in our own dispatch across the horizon is one of those 17 — safe for that fixture's claim, not a general fix.

The parity fixture cannot tell the two efficiencies apart. Storage's usage there is small (~0.5–1 MW) and nearly symmetric between charge and discharge, so transposing the two efficiency values is a near no-op (3.14e-4 MW residual against 3.01e-4 baseline noise). A magnitude sabotage on the same field is caught clearly (2.16 MW, ~200x tolerance), so storage is not decorative in the oracle comparison — but efficiency orientation is proved elsewhere, on a hand-built asymmetric fixture at the builder level, not at the oracle tier.

Using it

A 2-bus, 2-period arbitrage whose optimum is available in closed form. gcheap (10 $/MWh, 40 MW) and gexp (50 $/MWh) sit at the slack bus; a 20 MW load at b2 becomes 100 MW in the second period; a lossy 20 MW / 15 MWh unit sits beside it. Since c_H · η_c · η_d = 50 × 0.81 = 40.5 > 10 = c_L, arbitrage pays, and the energy cap — not the converter rating — is what binds:

from mambo_power import market
from mambo_power.model import (
    Branch,
    Bus,
    Generator,
    Load,
    Network,
    Period,
    PolynomialCost,
    Scenario,
    Storage,
)


def gen(gid: str, p_max_mw: float, price: float) -> Generator:
    return Generator(
        id=gid,
        bus="b1",
        p_mw=0,
        q_mvar=0,
        p_min_mw=0,
        p_max_mw=p_max_mw,
        q_min_mvar=0,
        q_max_mvar=0,
        v_set_pu=1.0,
        cost=PolynomialCost(coefficients=[price, 0.0]),
    )


net = Network(
    base_mva=100.0,
    buses=[Bus(id="b1", base_kv=138.0, type="slack"), Bus(id="b2", base_kv=138.0, type="pq")],
    branches=[Branch(id="br12", from_bus="b1", to_bus="b2", r=0.0, x=0.1, b=0.0)],
    generators=[gen("gcheap", 40.0, 10.0), gen("gexp", 200.0, 50.0)],
    loads=[Load(id="ld2", bus="b2", p_mw=20.0, q_mvar=0.0)],
    storage=[
        Storage(
            id="st2",
            bus="b2",
            p_max_mw=20.0,
            energy_mwh=15.0,
            soc_initial=0.0,
            efficiency_charge=0.9,
            efficiency_discharge=0.9,
        )
    ],
)
scenario = Scenario(
    network=net,
    periods=[Period(load_p_mw={"ld2": 20.0}), Period(load_p_mw={"ld2": 100.0})],
)
result = market.solve_multiperiod(scenario)
print(result.status, result.n_periods, round(result.objective_cost, 6))
for p in result.periods:
    st = p.storage[0]
    print(
        f"t={p.period}  lmp {p.buses[1].lmp:5.1f}  charge {st.charge_mw:9.6f}"
        f"  discharge {st.discharge_mw:9.6f}  soc {st.soc_mwh:6.3f}"
        f"  surplus {p.congestion_rent:.6f}"
    )
print(
    round(result.total_storage_discharge_revenue - result.total_storage_charge_payment, 6),
    "$ storage net revenue over the horizon",
)
Optimal 2 3091.666667
t=0  lmp  10.0  charge 16.666667  discharge  0.000000  soc 15.000  surplus -0.000000
t=1  lmp  50.0  charge  0.000000  discharge 13.500000  soc  0.000  surplus 0.000000
508.333333 $ storage net revenue over the horizon

Every figure is the closed form: charge* = min(20, 15/0.9) = 50/3 = 16.6667 MW (the energy cap binds, not the 20 MW rating), discharge* = 0.81 × 50/3 = 13.5 MW, and the horizon profit 50/3 × (40.5 − 10) = 508.3333 $. The two prices are formed by the builder's own balance rows, not assumed: gcheap is interior at t=0 so LMP = 10, and at t=1 it is at its cap with gexp interior so LMP = 50. The branch is unrated, so both periods' surpluses are zero — and they are zero only because storage is settled on both sides.

See 10_multiperiod_market.py for the full 24-hour version on case14: the storage schedule hour by hour, the cyclic SoC, two binding ramp rows with duals of opposite sign, the per-period settlement, and the periods=None degeneracy.

Jobs API

market.multiperiod is a registered jobs kind, and it is the reason SolveRequest now accepts either a network or a scenario: a horizon needs Scenario.periods, which a bare Network cannot supply.

from mambo_power import jobs

outcome = jobs.run(jobs.SolveRequest(kind="market.multiperiod", scenario=scenario))
print(outcome.status, outcome.result.n_periods)
ok 2

A SolveRequest carrying a network still works for this kind too — it is wrapped as a single-period Scenario, and the clearing degenerates to the nodal one. A non-"Optimal" status comes back as a structured failure (INFEASIBLE_LP or UNBOUNDED_LP) through the same non-Optimal-status translation opf.dc and market.nodal use, not as a "successful" result carrying a meaningless dispatch. See Jobs API › Failures are data.