File formats

mambo_power.io holds importers and exporters. Every format speaks only mambo_power.model: an importer produces a validated Network, an exporter consumes one, and neither touches arrays or solvers. Six formats ship: the native JSON format, the MATPOWER .m importer, pandapower JSON both ways, PyPSA export, the PSS/E RAW v33 importer and the CSV bundle. Every importer returns an ImportReport and every exporter an ExportReport (see io.report) with one rule: an empty report means the conversion was lossless; anything dropped, approximated or repaired is an issue naming the element id and the field. io.limitations.LIMITATIONS maps each module to every code it can emit, and each code is documented on this page.

Native JSON

The native format is the Network model serialised by pydantic — there is no separate schema to keep in sync. mambo_power.io.native wraps the four operations:

Function Does
native.dumps(net) -> str Indented JSON, None fields omitted.
native.loads(text) -> Network Parse and validate; raises NetworkValidationError or pydantic's ValidationError.
native.save(net, path) Write dumps output as UTF-8 with a trailing newline.
native.load(path) -> Network Read a file into a validated Network.

loads(dumps(net)) == net holds for every valid network (tested on every fixture).

A minimal document — two buses, one line, one generator, one load:

{
  "schema_version": 1,
  "base_mva": 100.0,
  "buses": [
    {"id": "b1", "base_kv": 110.0, "type": "slack", "in_service": true},
    {"id": "b2", "base_kv": 110.0, "type": "pq", "in_service": true}
  ],
  "branches": [
    {"id": "l12", "from_bus": "b1", "to_bus": "b2", "r": 0.01, "x": 0.1, "b": 0.02, "in_service": true}
  ],
  "generators": [
    {"id": "g1", "bus": "b1", "p_mw": 0.0, "q_mvar": 0.0,
     "p_min_mw": 0.0, "p_max_mw": 200.0, "q_min_mvar": -100.0, "q_max_mvar": 100.0,
     "v_set_pu": 1.0, "in_service": true}
  ],
  "loads": [
    {"id": "d2", "bus": "b2", "p_mw": 50.0, "q_mvar": 10.0, "in_service": true}
  ],
  "shunts": [],
  "storage": [],
  "zones": []
}

Rules worth knowing:

  • schema_version is 1 and is the only accepted value; a future breaking change bumps it.
  • Optional fields (vm_pu, rating_mva, cost, ...) may be omitted or written as null; on write they are omitted.
  • Unknown keys anywhere are an error. Non-finite numbers are an error.
  • The JSON schema for validators and editors comes from Network.json_schema() (see Network model › JSON schema).

MATPOWER .m importer

mambo_power.io.matpower reads MATPOWER case files — the de-facto exchange format for academic test systems. It is a parser, not a MATLAB interpreter: it recognises mpc.<name> = <scalar>;, mpc.<name> = [ rows ]; and mpc.<name> = { ... }; statements, tolerates % comments, tabs, blank lines, CRLF line endings, a UTF-8 BOM, scientific notation, rows split by ; or by newlines, and ignores every field it does not know.

Function Does
matpower.load(path) -> Network Parse a file; repair warnings discarded.
matpower.loads(text) -> Network Parse case text.
matpower.load_with_report(path) -> (Network, ImportReport) Parse and return the repairs performed as typed ImportIssue entries (code, message, bus and element ids).
matpower.loads_with_report(text) -> (Network, ImportReport) Same, from text.
matpower.load_with_warnings(path) -> (Network, list[str]) The legacy form: one CODE: message string per repair — exactly report.as_strings().
matpower.loads_with_warnings(text) -> (Network, list[str]) Same, from text.

The path/text split follows the json module precedent; the importer never sniffs whether a string is a path or a document.

Sections read

mpc.baseMVA (required), mpc.bus, mpc.gen, mpc.branch (required), mpc.gencost (optional). mpc.version is not checked — the caseformat v2 column layout is assumed. mpc.bus_name, mpc.areas and any user-defined fields are skipped.

Derived ids

Element Id Emitted
Bus bus-<BUS_I> every row
Generator gen-<row> (1-based row in mpc.gen) every row
Branch branch-<row> (1-based row in mpc.branch) every row
Load load-<BUS_I> only when PD != 0 or QD != 0
Shunt shunt-<BUS_I> only when GS != 0 or BS != 0
Zone <ZONE> as a compact string (1.0"1") one per distinct ZONE value

Column map — mpc.bus

Col MATPOWER Field Notes
1 BUS_I id = "bus-<n>" must be integer-valued
2 BUS_TYPE type, in_service 1 → pq, 2 → pv, 3 → slack, 4 → pq with in_service=False; anything else is BAD_NUMBER
3 PD Load.p_mw with col 4, emitted as load-<n> when non-zero
4 QD Load.q_mvar
5 GS Shunt.g_mw with col 6, emitted as shunt-<n> when non-zero
6 BS Shunt.b_mvar
7 BUS_AREA area compact string
8 VM vm_pu
9 VA va_deg
10 BASE_KV base_kv <= 0 is replaced by 1.0 with a warning
11 ZONE zone (+ a Zone) compact string
12 VMAX v_max_pu
13 VMIN v_min_pu
14–17 LAM_P, LAM_Q, MU_VMAX, MU_VMIN dropped OPF result columns

Column map — mpc.gen

Col MATPOWER Field Notes
1 GEN_BUS bus = "bus-<n>"
2 PG p_mw
3 QG q_mvar
4 QMAX q_max_mvar
5 QMIN q_min_mvar
6 VG v_set_pu
7 MBASE dropped machine base; all quantities are on the system base
8 GEN_STATUS in_service > 0 is in service
9 PMAX p_max_mw
10 PMIN p_min_mw
11–21 PC1APF dropped capability-curve and AGC columns
22–25 MU_* dropped OPF result columns

Column map — mpc.branch

Col MATPOWER Field Notes
1 F_BUS from_bus
2 T_BUS to_bus
3 BR_R r pu
4 BR_X x pu
5 BR_B b pu, total charging
6 RATE_A rating_mva 0 means unrated → None
7–8 RATE_B, RATE_C dropped short-term / emergency ratings
9 TAP tap_ratio 0 means nominal → None
10 SHIFT shift_deg 0None
11 BR_STATUS in_service > 0 is in service
12–13 ANGMIN, ANGMAX dropped angle-difference limits
14–21 PFMU_ANGMAX dropped power-flow / OPF result columns

mpc.gencost

Col MATPOWER Field
1 MODEL 2PolynomialCost, 1PiecewiseCost; anything else is BAD_NUMBER
2 STARTUP startup
3 SHUTDOWN shutdown
4 NCOST number of coefficients (MODEL 2) or breakpoints (MODEL 1); must be ≥ 1
5… COST MODEL 2: NCOST coefficients highest order first → coefficients; MODEL 1: NCOST pairs (p, cost)points

Accepted shapes: exactly ngen rows (one per generator), or 2 * ngen rows (reactive-power costs appended) — the second half is ignored with a warning. Any other row count is BAD_ROW. When mpc.gencost is absent every generator has cost=None.

Warnings (repairs)

Conditions that are repaired rather than rejected are reported by load_with_report / loads_with_report as an ImportReport whose .warnings are typed ImportIssue records (code, message, bus_ids, element_ids; .codes is the set of distinct codes), and by load_with_warnings / loads_with_warnings as the same entries rendered CODE: message:

Code Repair
BASE_KV_REPLACED BASE_KV <= 0 becomes 1.0 (CDF-derived cases store 0 for "unknown"); one issue per bus, naming the bus (bus_ids) and the line.
GENCOST_REACTIVE_IGNORED mpc.gencost had 2 * ngen rows; the second half (reactive costs) was dropped.
ISLAND_DEACTIVATED Buses the slack cannot reach over in-service branches were switched off together with their generators, loads, shunts and storage; one issue per island, bus_ids and element_ids list what was switched off (decision D1).

load / loads apply the same repairs and discard the report.

from mambo_power.io import matpower

net, report = matpower.load_with_report("fixtures/matpower/derived/case14_island.m")
print(sorted(report.codes), len(report.warnings))
island = next(w for w in report.warnings if w.code == "ISLAND_DEACTIVATED")
print(island.bus_ids, island.element_ids)
print(str(island))
['BASE_KV_REPLACED', 'ISLAND_DEACTIVATED'] 15
['bus-8'] ['gen-5']
ISLAND_DEACTIVATED: bus bus-8 cannot reach slack bus bus-1 over in-service branches; deactivated with attached elements [gen-5]

Islands

The model rejects a network with an in-service bus that cannot reach the slack (DISCONNECTED_BUS), because such a bus has no reference angle. Real files contain islands — a branch out of service that splits off a sub-network. The importer therefore repairs before it validates: every bus outside the slack's component is set in_service=False, so is every element attached to those buses, and one ISLAND_DEACTIVATED warning lists them. The resulting Network is valid and solves on the main island; the deactivated elements remain in the file for inspection. Building the same Network(...) by hand still raises — the importer repairs, the model stays strict. The shared implementation, model.repair_islands, is what every later importer must call too. 05_roles_and_islands.py walks through the repaired fixture and the model's rejection of the same network.

Errors

Anything wrong with the file raises MatpowerImportError with a stable code and a 1-based line when known:

Code Cause
MISSING_BASE_MVA No mpc.baseMVA = ...; statement.
MISSING_SECTION mpc.bus, mpc.gen or mpc.branch matrix not found.
UNTERMINATED_MATRIX A [ or { block never closed.
BAD_NUMBER A token is not a finite number; a column that must be an integer is not; BUS_TYPE not in 1–4; gencost MODEL not 1 or 2; NCOST < 1.
BAD_ROW A row narrower than the minimum for its matrix (bus 13, gen 10, branch 11, gencost 4), ragged rows, a gencost row too short for its NCOST, or a gencost row count that is neither ngen nor 2 * ngen.

Anything wrong with the network — no slack, a dangling bus reference, inverted limits — is left to Network validation and raises NetworkValidationError (see validation codes).

Limitations

  • Only the caseformat v2 column layout is supported; v1 files (no mpc. prefix, different branch columns) are not recognised.
  • Dropped columns (listed above): MBASE, PC1APF, RATE_B/RATE_C, ANGMIN/ANGMAX, every MU_* / LAM_* and stored-result column. Re-exporting a case is therefore lossy for those fields (an exporter is not shipped yet).
  • mpc.bus_name is ignored because Bus carries no name field.
  • No DC lines (mpc.dcline), no three-winding transformers, no three-phase data.
  • The reactive half of a 2 * ngen gencost is dropped, not stored.

Example

from mambo_power.io import matpower

net, warnings = matpower.load_with_warnings("fixtures/matpower/case14.m")
print(len(net.buses), len(warnings), warnings[0])
14 14 BASE_KV_REPLACED: bus-1: BASE_KV is 0; base_kv set to 1.0 (line 25)

pandapower JSON

mambo_power.io.pandapower_json reads and writes the JSON that pandapower's pp.to_json / pp.from_json produce and consume — a pandapowerNet document with one table per element type. pandapower itself is imported lazily, inside the functions that need it, so mambo_power keeps its zero-optional-dependency import; both directions need pandapower installed only when they run. Every conversion is best effort + report: anything the other side cannot hold is dropped or repaired and named in the report with the element id and the field; an empty report means the conversion was lossless. Nothing is logged or printed.

Function Does
pandapower_json.load(path) -> Network Read a pp.to_json file; repair report discarded.
pandapower_json.loads(text) -> Network Same, from text.
pandapower_json.load_with_report(path) -> (Network, ImportReport) Read and return every drop and repair as typed ImportIssue entries.
pandapower_json.loads_with_report(text) -> (Network, ImportReport) Same, from text.
pandapower_json.dumps(net, *, f_hz=50.0) -> str Write a document pp.from_json loads; report discarded.
pandapower_json.dump(net, path, *, f_hz=50.0) Same, to a file.
pandapower_json.dumps_with_report(net, *, f_hz=50.0) -> (str, ExportReport) Write and return what pandapower could not carry.

f_hz is pandapower's system frequency (its create_empty_network default is 50 Hz); it enters only the c_nf_per_km conversion below, and the importer reads the document's own f_hz.

Tables read

bus, ext_grid, gen, sgen, load, shunt, line, trafo (two-winding), poly_cost, pwl_cost. Results tables (res_bus, res_line, ...) are neither read nor written — the wave's scope excludes pandapower results, and a solved res_bus in the file is a result, not model data. The slack bus is the one bus with a state after import: its vm_pu / va_deg come from the ext_grid row's vm_pu / va_degree (the setpoint the slack holds), and every other bus has None — the warm-start rule in the model page (every in-service bus carries both) does not apply to an imported file. On export the same holds in reverse: a stored state on any other bus is not written and is named, once, in a FIELD_DROPPED issue whose bus_ids list them. Every other non-empty table — trafo3w, switch, impedance, ward, xward, dcline, storage, motor, asymmetric_*, ... — is dropped row by row with ELEMENT_DROPPED, so the report says exactly what was left behind.

Derived ids

Import takes the row's name when it is present and not empty, else <table>-<index> (bus-3, trafo-0, ext_grid-0). pp.networks.case14() names its buses 114 and leaves its branches unnamed, so the imported ids are "1", line-0, trafo-0. Export writes the mambo id into name, so a network survives a round trip with its ids intact. Zones come from bus.zone — one Zone per distinct value, id = the compact string form (1.0"1").

Bus roles and the ext_grid rule

pandapower has no bus type column; roles come from what is connected. On import the first in-service ext_grid is the slack (its bus is slack, the ext_grid row becomes the slack generator with v_set_pu = vm_pu and limits from min/max_p_mw, min/max_q_mvar); every further in-service ext_grid is demoted to a PV generator with EXTRA_EXT_GRID_DEMOTED, because the model has exactly one slack. With no in-service ext_grid — none at all, or every one switched off — the first in-service gen with slack = True (pandapower's own ext_grid-less reference bus, which runpp solves) is the slack, reported GEN_SLACK_PROMOTED, with vm_pu from gen.vm_pu and va_deg = 0; a gen.slack = True beside a live ext_grid stays a PV generator and the flag is COLUMN_DROPPED. A file with neither a live ext_grid nor a live slack gen has no reference bus, and the import ends in NetworkValidationError (NO_SLACK) — the network is what the file says, and the model refuses it, as it refuses a MATPOWER case with no type-3 bus. A bus with an in-service gen is pv; everything else is pq. sgen rows become generators on their PQ bus (v_set_pu = 1.0, p/q scaled by scaling). On export the rule runs backwards: the first in-service generator on the slack bus becomes ext_grid, PV-bus generators become gen, PQ-bus generators become sgen.

Unit conversions (measured on pandapower 3.3.0)

All impedances are per unit on sn_mva and the from-bus voltage; Zb = vn_kv² / sn_mva.

pandapower Field Conversion
line.r_ohm_per_km, length_km, parallel r r_ohm_per_km · length / parallel / Zb (same for x)
line.c_nf_per_km b 2π·f_hz · c_nf_per_km·1e-9 · length · parallel · Zb
line.max_i_ka, df rating_mva max_i_ka · df · parallel · √3 · vn_kv(from)
trafo.vk_percent, vkr_percent, sn_mva, vn_lv_kv x, r z = vk/100 · sn_mva/sn_trafo · (vn_lv_kv / vn(lv bus))² / parallel, r likewise from vkr, x = √(z² − r²) — on the system base
trafo.vn_hv_kv, vn_lv_kv, tap_* tap_ratio, shift_deg (vn_hv_kv/vn(hv bus)) / (vn_lv_kv/vn(lv bus)) after the tap changer has scaled the tapped winding, by pandapower 3.3's own rule (build_branch._calc_tap_from_dataframe): tap_changer_type = None applies no tap (the columns are inert in pandapower too; a non-neutral tap_pos is COLUMN_DROPPED); a pre-3.0 table with a tap_phase_shifter column and no tap_changer_type is read as pandapower 3.3's deprecation branch still does, True as "Ideal" and False as "Ratio"; "Ratio" / "Symmetrical" scale the winding by 1 + (tap_pos − tap_neutral)·tap_step_percent/100, rotated by tap_step_degree when it is set (which also adds to shift_deg); "Ideal" adds ±(tap_pos − tap_neutral)·tap_step_degree (or the arcsin-of-percent form) to shift_deg and leaves the ratio alone; a second changer (tap2_*, pandapower ≥ 3.0) is applied after the first on the winding it left, shifts adding, as pandapower loops its prefixes. from_bus = hv_bus (mambo's tap side)
trafo.shift_degree, sn_mva shift_deg, rating_mva as is
shunt.p_mw, q_mvar, step, vn_kv g_mw, b_mvar pandapower's values are consumption, mambo's b_mvar is injection: b_mvar = −q_mvar · step · (vn(bus)/vn_kv)², g_mw = p_mw · step · (vn(bus)/vn_kv)²
poly_cost.cp2/cp1/cp0 PolynomialCost.coefficients = [c2, c1, c0] both ways; the cq* columns are dropped
pwl_cost.points = [[p0, p1, slope], ...] PiecewiseCost.points breakpoints with the cost at p0 taken as 0 — pandapower has no offset column
bus.vn_kv, min/max_vm_pu, zone, geo, in_service base_kv, v_min/max_pu, zone, geo, in_service Bus.area travels as an extra bus.area column (pandapower keeps unknown columns through to_json, measured)

On export a nominal-tap transformer (tap_ratio None or 1.0) is written with no tap changer — tap_side None, tap_neutral / tap_pos / tap_step_percent NaN, the columns pandapower itself leaves empty on such a transformer (its networks.case14() stores two that way); an off-nominal one with tap_side = "hv", tap_neutral = 0, tap_pos = ±1 and tap_step_percent = |tap_ratio − 1|·100, which is pandapower's own from_ppc encoding. Both re-import to the same ratio. A transformer without rating_mva is written with sn_mva = base_mva and FIELD_DEFAULTED, because pandapower needs a rated power to compute its impedance — it re-imports as a rating.

Warnings (repairs)

Code Direction Repair
EXTRA_EXT_GRID_DEMOTED import A second in-service ext_grid; imported as a PV generator (one slack). bus_ids names the bus.
GEN_SLACK_PROMOTED import No in-service ext_grid; the first in-service gen with slack = True became the slack generator (bus_ids names the bus, element_ids the generator).
COLUMN_DROPPED import A column the model has no place for held a non-inert value (bus.type != "b", gen.slack beside a live ext_grid, gen.slack_weight, line.g_us_per_km, trafo.pfe_kw / i0_percent, a trafo.tap_pos off neutral under tap_changer_type = None (pandapower applies no tap either), a trafo.tap_pos whose tap_neutral is NaN — create_transformer_from_parameters's own default — under a changer type (pandapower's step is NaN and counts as 0: no tap on either side), load.const_z_* / const_i_*, *.max_loading_percent, *.controllable, ...); the message names table, row, column and value.
TAP_CHANGER_TYPE_UNSUPPORTED import A trafo tap changer neither pandapower nor the model can express as a ratio and a shift: an unknown tap_changer_type, an "Ideal" shifter with both tap_step_percent and tap_step_degree set (runpp refuses it too), or a tap_side that is neither hv nor lv. Imported at the nominal tap; the message names the transformer.
ELEMENT_DROPPED both Import: a row of a table that is not read (trafo3w, switch, storage, ...) or a poly_cost / pwl_cost row that is not a generator's active-power cost. Export: a Storage unit (pandapower's storage has no efficiency columns).
FIELD_DEFAULTED both Import: a missing or NaN limit column (min/max_p_mw, min/max_q_mvar on ext_grid / gen / sgen) set to the element's setpoint, so the limits pin the setpoint rather than invent a range. Export: an unrated transformer's sn_mva set to base_mva.
ISLAND_DEACTIVATED import As for MATPOWER: buses that cannot reach the slack are switched off with their elements (islands).
FIELD_DROPPED export A model field with no pandapower column: Zone.name, a stored Bus.vm_pu / va_deg on any bus but the slack (results tables are not written; one issue, bus_ids names them), generator ramp_up_mw / ramp_down_mw, the slack generator's p_mw / q_mvar (ext_grid has no setpoint), a PV generator's q_mvar, an sgen's v_set_pu, a transformer's b (no line charging on a trafo), cost.startup / cost.shutdown, and a piecewise cost's offset points[0][1].
COST_DROPPED export A polynomial cost of degree > 2 (poly_cost holds cp0..cp2); dropped, never approximated.
BID_DROPPED export A load's demand bid (pandapower has no elastic demand); the load is written as a fixed p_mw.

Errors

A document that is not a pandapowerNet JSON, a table without its required columns, or a reference to a missing bus raises pandapower's or pydantic's own exception; anything wrong with the resulting network (no slack, inverted limits) raises NetworkValidationError as for every format.

Limitations

  • Three-winding transformers, switches, impedances, wards, DC lines, motors and every asymmetric table are dropped (and reported), not modelled; a switch that opens a line is not applied to in_service.
  • The tap changer is folded into tap_ratio / shift_deg exactly as pandapower 3.3 applies it (table above), so a tap_pos under tap_changer_type = None — pandapower's default from create_transformer_from_parameters — is inert on both sides; the changer's position itself (tap_pos, tap_min, tap_max) is not a model field and does not survive a round trip (the export writes a ±1 position encoding the ratio).
  • Round trip, measured (F2): pp.toolbox.nets_equal(from_json(dumps(loads(to_json(pn)))), pn) holds for poly_cost and pwl_cost only. bus, ext_grid, gen, sgen, load, shunt, line and trafo fail strict equality on name (None in pandapower vs our ids), dtype (bus.name int vs str, bus.zone 1.0 vs "1"), the default-column sets create_* adds versus from_ppc, and 5e-13 float noise on vk_percent / tap_step_percent — never on a carried value: every value column the model holds survives at 1e-12 (tests/unit/test_io_pandapower_json.py::test_nets_equal_round_trip_measured pins the set).
  • pandapower's own solvers agree with mambo's on the exported document: rundcpp vs pf.solve_dc to 1.3e-13° and runpp vs pf.solve_ac to 2.4e-15 pu on case14 / case30 / case57 (tests/parity/test_pandapower_json_vs_pandapower.py).

Example

import pandapower as pp
import pandapower.networks as pn

from mambo_power.io import pandapower_json

net, report = pandapower_json.loads_with_report(pp.to_json(pn.case14()))
print(len(net.buses), len(net.branches), [b.id for b in net.branches if b.kind == "transformer"])
print(sorted(report.codes), len(report.warnings))
14 20 ['trafo-0', 'trafo-1', 'trafo-2', 'trafo-3', 'trafo-4']
[] 0

PyPSA export

mambo_power.io.pypsa turns a Network into a pypsa.Network — export only; PyPSA is imported lazily inside the two functions. The field map was verified against opf.solve_dc_opf: PyPSA's optimize() on the exported network reproduces mambo's DC-OPF objective on every bundled case (tests/parity/test_pypsa_export_vs_pypsa.py).

Function Does
pypsa.to_network(net) -> pypsa.Network Export; report discarded.
pypsa.to_network_with_report(net) -> (pypsa.Network, ExportReport) Export and return what PyPSA cannot carry.

Field map

Model PyPSA Notes
Bus Bus v_nom = base_kv, v_mag_pu_min/max, control (Slack / PV / PQ) from type, x/y from geo (lon, lat), v_mag_pu_set from the bus's in-service generators' v_set_pu. area, zone and in_service ride along as custom bus columns (PyPSA buses have no active flag); every element at an out-of-service bus is exported active = False, which is what numerics.NetworkArrays does with them.
Branch with is_transformer false (a line at nominal tap) Line Physical units on the from-bus base, Zb = base_kv² / base_mva: r, x in ohm (× Zb), b in siemens (÷ Zb).
Branch with is_transformer (kind == "transformer" or an off-nominal tap/shift) Transformer(model="pi") r, x, b per unit on the transformer's own s_nom (impedances r, x × s_nom / base_mva; the admittance b × base_mva / s_nom), tap_ratio, tap_side = 0 (mambo's tap is on the from side), phase_shift in degrees.
rating_mva s_nom An unrated branch gets s_nom = 1e5 (pypsa.UNRATED_S_NOM_MVA): PyPSA's optimiser reads s_nom == 0 as "carries nothing", not "unlimited". Reported per branch as PYPSA_UNRATED_S_NOM_DEFAULTED.
Generator Generator p_nom = max(abs(p_min_mw), abs(p_max_mw)), p_min_pu / p_max_pu as fractions of it (so p_nom == p_max_mw in the ordinary case and a negative-only range survives), marginal_cost = c1, marginal_cost_quadratic = c2, ramp_limit_up/down as fractions of p_nom, start_up_cost / shut_down_cost, control, active.
constant cost term c0 marginal_cost_constant A custom column (pypsa.COST_CONSTANT_COLUMN): n.objective excludes constants, so the value is carried beside the objective, not in it.
Load Load(p_set, q_set)
Shunt ShuntImpedance(g, b) siemens, MW / kV².
Storage StorageUnit p_nom, max_hours, state_of_charge_initial, efficiency_store, efficiency_dispatch.
base_mva n.meta["base_mva"]

p_set is never written on a generator. A non-NaN p_set pins the dispatch in optimize() — that was the root cause behind M3's first PyPSA parity mismatch.

Warnings (dropped or defaulted, never silently)

Code Dropped
PYPSA_PWL_COST_DROPPED A piecewise-linear cost; the generator is exported with marginal_cost 0.
PYPSA_COST_DEGREE_DROPPED A polynomial cost of effective degree > 2; exported with marginal_cost 0.
PYPSA_LOAD_BID_DROPPED A load's demand bid; the load is exported as a fixed p_set.
PYPSA_ZONE_DROPPED The zones list (PyPSA has no zone component); the bus zone column still names them.
PYPSA_GEN_Q_LIMITS_DROPPED q_min_mvar / q_max_mvar (PyPSA generators carry no reactive limits).
PYPSA_GEN_RAMP_DROPPED A ramp on a zero-capacity generator (cannot be a fraction of p_nom = 0).
PYPSA_GEN_VSET_CONFLICT In-service generators at one bus disagreeing on v_set_pu; PyPSA has one v_mag_pu_set per bus, the first in-service generator's wins (out-of-service units do not take part).
PYPSA_COST_NONCONVEX A quadratic cost with c2 < 0 (concave). Exported unchanged as marginal_cost_quadratic — nothing is dropped — but PyPSA's solver will reject the non-convex objective with its own error, so the report names the generator up front.
PYPSA_UNRATED_S_NOM_DEFAULTED A branch with rating_mva = None, written with s_nom = 1e5 (pypsa.UNRATED_S_NOM_MVA); one entry per branch naming it and the sentinel.

Every issue names the element id and the field. The exporter raises nothing of its own: a Network is already valid, and PyPSA's constructors are given only values they accept.

Limitations

  • PyPSA cannot express piecewise costs, polynomial costs of degree > 2, demand bids, zones or generator reactive limits (measured on PyPSA 1.2.4); each is dropped and reported under the codes above.
  • PyPSA 1.2.4's optimize() ignores phase_shift — only lpf() / pf() read it. The exporter carries the shift faithfully (n.lpf() agrees with pf.solve_dc on a shifted loop, sign included), so it is not reported, but DC-OPF parity is a statement about shift-free networks.
  • Parity, measured (F3): the DC-OPF objective agrees to 1e-8 relative on case14, case30 and case118 (worst 1.3e-12) and the dispatch to 1e-4 MW on case14 and case30. On case118 one generator differs by 1.87e-3 MW — the oracle's residual, not the mapping's: both dispatches balance 4242.0 MW, the exact polynomial puts mambo's point 1.6e-7 $/h below PyPSA's, and HiGHS reports a 1.1e-6 primal-dual objective error that no tolerance or algorithm setting moves. The parity test pins 2e-3 MW for case118 only.

Example

from mambo_power.io import matpower, pypsa

net = matpower.load("fixtures/matpower/case14.m")
n, report = pypsa.to_network_with_report(net)
print(sorted(report.codes), len(report.warnings))
print(n.generators[["p_nom", "marginal_cost", "marginal_cost_quadratic"]].head(2))
['PYPSA_GEN_Q_LIMITS_DROPPED', 'PYPSA_UNRATED_S_NOM_DEFAULTED', 'PYPSA_ZONE_DROPPED'] 26
       p_nom  marginal_cost  marginal_cost_quadratic
name
gen-1  332.4           20.0                 0.043029
gen-2  140.0           20.0                 0.250000

PSS/E RAW v33 importer

mambo_power.io.psse_raw reads PSS/E RAW files in the version 33 layout only (REV must be 33). It is a record parser: fields are comma-separated, single-quoted strings may contain commas and slashes, / outside quotes starts a comment, blank lines are skipped, each section ends with a line whose first field is 0, and Q (or the end of the text) after the zone section ends the file. Field order and units follow grg-pssedata's struct.py; every conversion follows MATPOWER's psse_convert.m / psse_convert_xfmr.m.

Function Does
psse_raw.load(path) -> Network Parse a file; report discarded.
psse_raw.loads(text) -> Network Parse RAW text.
psse_raw.load_with_report(path) -> (Network, ImportReport) Parse and return every fold, drop and repair.
psse_raw.loads_with_report(text) -> (Network, ImportReport) Same, from text.

Sections read

Case identification (SBASEbase_mva), bus, load, fixed shunt, generator, non-transformer branch, transformer (two-winding, the four-line record), area, zone. Every other section — two-terminal and VSC DC lines, impedance-correction tables, multi-terminal DC, multi-section lines, inter-area transfers, owners, FACTS, switched shunts, GNE devices, induction machines — is skipped with one report entry per record. Three-winding transformer records (five lines, K != 0) inside the transformer section are skipped the same way. Sections through zone must be present and terminated.

Derived ids

Element Id
Bus bus-<I>
Load / fixed shunt / generator load-<I>-<ID>, shunt-<I>-<ID>, gen-<I>-<ID> (ID stripped of blanks)
Branch and two-winding transformer branch-<I>-<J>-<CKT>
Folded branch end shunt shunt-branch-<I>-<J>-<CKT>-i / -j
Folded transformer magnetising shunt shunt-xfmr-<I>-<J>-<CKT>
Zone <ZONE> as a compact string; one per distinct value

Record map

Record Fields used Field
bus I, NAME, BASKV, IDE, AREA, ZONE, OWNER, VM, VA[, NVHI, NVLO] base_kv (<= 01.0 with BASE_KV_REPLACED), type / in_service (IDE 1 → pq, 2 → pv, 3 → slack, 4 → pq out of service), area, zone, vm_pu, va_deg, v_max_pu, v_min_pu; NAME and OWNER dropped
load I, ID, STATUS, AREA, ZONE, PL, QL, IP, IQ, YP, YQ p_mw, q_mvar; a non-zero IP IQ YP YQ is folded as P = PL + IP·VM + YP·VM² at the bus's VM (RAW_LOAD_ZIP_FOLDED)
fixed shunt I, ID, STATUS, GL, BL g_mw, b_mvar (MW / MVAr at 1 pu)
generator I, ID, PG, QG, QT, QB, VS, ..., STAT, ..., PT, PB p_mw, q_mvar, q_max_mvar, q_min_mvar, v_set_pu, in_service, p_max_mw, p_min_mw; cost = None (RAW_NO_COSTS); IREG, MBASE, ZR/ZX, RT/XT, GTAP, RMPCT, owners and WMOD/WPF dropped
branch I, J, CKT, R, X, B, RATEA, ..., GI, BI, GJ, BJ, ST r, x, b (pu on SBASE), rating_mva (RATEA, 0None), in_service, kind = "line"; end shunts become Shunt entries (RAW_BRANCH_END_SHUNT_FOLDED); RATEB/C, LEN, owners dropped
transformer (4 lines) line 1 I, J, K, CKT, CW, CZ, CM, MAG1, MAG2, ..., STAT; line 2 R1-2, X1-2, SBASE1-2; line 3 WINDV1, NOMV1, ANG1, RATA1; line 4 WINDV2, NOMV2 r, x, tap_ratio, shift_deg = ANG1, rating_mva = RATA1, b = 0, kind = "transformer" (set from the record, not inferred from the tap); magnetising admittance becomes a Shunt at the from bus (RAW_XFMR_MAGNETISING_FOLDED)
zone I, ZONAME zone names → Zone.name. The area section is not read — only the bus AREA labels survive, as Bus.area — so each area record (I, ISW, PDES, PTOL, ARNAME) is reported RAW_SECTION_IGNORED

The CZ / CW / CM conversions

Code Meaning Conversion (MATPOWER's)
CZ = 1 R1-2, X1-2 pu on SBASE as is
CZ = 2 pu on SBASE1-2 and NOMV1 (0 = the from bus's base kV) scaled by (NOMV1 / BASKV_I)² · SBASE / SBASE1-2
CZ = 3 R1-2 = load loss in W, X1-2 = abs(Z) pu on the winding base R = R/(1e6·SBASE1-2), X = √(Z² − R²), then scaled as for 2
CW = 1 WINDV pu of bus base kV t = WINDV
CW = 2 WINDV in kV t = WINDV / BASKV
CW = 3 WINDV pu of NOMV t = WINDV · NOMV / BASKV
tap_ratio = t1 / t2
CM = 1 MAG1 + j·MAG2 pu on SBASE shunt G + jB at the from bus
CM = 2 MAG1 = no-load loss in W, MAG2 = exciting current pu on the winding base G = MAG1/(1e6·SBASE1-2), B = −√(MAG2² − G²), both scaled to the system base

Warnings (repairs and folds)

Code Repair
BASE_KV_REPLACED BASKV <= 0 becomes 1.0; one issue per bus, as for MATPOWER.
ISLAND_DEACTIVATED Buses that cannot reach the slack are switched off with their elements (islands).
RAW_NO_COSTS Emitted once per file: RAW has no cost section, so every generator imports with cost = None.
RAW_LOAD_ZIP_FOLDED A load's constant-current / constant-admittance parts were folded into p_mw / q_mvar at the bus's stored VM.
RAW_BRANCH_END_SHUNT_FOLDED A branch's GI/BI or GJ/BJ became a Shunt at that end.
RAW_XFMR_MAGNETISING_FOLDED A transformer's MAG1/MAG2 became a Shunt at the from bus.
RAW_THREE_WINDING_IGNORED A three-winding transformer record was skipped (one issue per record).
RAW_SWITCHED_SHUNT_IGNORED A switched shunt was skipped; its BINIT is not folded into a fixed shunt (bus_ids names the bus).
RAW_SECTION_IGNORED A record of a section that is not read (areas, owners, DC lines, FACTS, ...) was skipped; one issue per record naming the section and the key.

Errors

Anything wrong with the file raises RawImportError with a stable code and a 1-based line when known. This is the one importer with its own exception: a RAW file is read record by record and the first structural fault (a missing terminator, a bad REV) makes everything after it unreadable, so it stops there with the line number; the CSV bundle, whose tables are independent, collects every problem into an ImportReport and raises ReportError instead (its Errors section below). Both are ValueErrors. RawImportError codes are the RawImportCode literal, not ImportIssueCode:

Code Cause
BAD_HEADER Fewer than three case-identification lines, or IC != 0 (only a full case is read).
UNSUPPORTED_VERSION REV is not 33.
BAD_NUMBER A token that is not a finite number where one is required; IDE not in 1–4; CZ / CW not in 1–3; CZ 2 or 3 with SBASE1-2 <= 0; CZ = 3 with abs(Z) < R.
BAD_RECORD A record with fewer fields than its layout needs, or a multi-line record the file ends inside.
UNTERMINATED_SECTION A section (through zone) without its 0 terminator. When the next 0 line's comment names a later section (0 / END OF LOAD DATA while buses are still being read), the message names the section that lacks its terminator and line is that 0 line; without such a comment it names the section the file ended in, at the line it ended, and says an earlier terminator is the likely defect.
UNKNOWN_BUS A load, shunt, generator, branch or transformer naming a bus number the bus section does not have.

Anything wrong with the network raises NetworkValidationError, as for every format.

Limitations

  • Version 33 only. Older layouts (v30–v32 differ in the bus and transformer records) and the v34+ layouts are refused with UNSUPPORTED_VERSION.
  • No costs: an imported RAW network flows (pf); opf.solve_dc_opf and every market clearing on it raise mambo_power.opf.MissingCostError (a ValueError) naming every generator without a cost, before any solve — and jobs.run reports that as a VALIDATION failure. The importer never invents costs; set Generator.cost on each generator, or take it out of service, before pricing dispatch (costs= is opf.gen_cost_coeffs's own overlay, which market.solve_agents fills from the strategies; no solve_* takes it).
  • Three-winding transformers, switched shunts, DC lines, FACTS, impedance-correction tables and owners are skipped, not modelled. A switched shunt's BINIT is not folded, so a case whose voltage profile relies on it solves to a different voltage.
  • Transformers have b = 0; the magnetising branch is a bus shunt, not line charging.
  • Only RATEA becomes rating_mva; RATEB / RATEC are dropped.

Example

from mambo_power.io import psse_raw

net, report = psse_raw.load_with_report("fixtures/case14_v33.raw")
print(len(net.buses), len(net.branches), sorted(report.codes), len(report.warnings))
print([b.id for b in net.branches if b.kind == "transformer"])
print(next(str(w) for w in report.warnings if w.code == "RAW_NO_COSTS"))
14 20 ['BASE_KV_REPLACED', 'RAW_NO_COSTS', 'RAW_SECTION_IGNORED'] 16
['branch-4-7-1', 'branch-4-9-1', 'branch-5-6-1']
RAW_NO_COSTS: RAW carries no cost data; all 5 generators imported with cost=None

fixtures/case14_v33.raw is IEEE case14 re-spelled as a RAW file (provenance in fixtures/PROVENANCE-raw.md); fixtures/synthetic_quirks_v33.raw exercises every fold and skip above.

CSV bundle

mambo_power.io.csv_bundle writes a Network as one directory — manifest.json plus one CSV per entity table — and reads it back identically: load(dump(net)) == net and every numerics.NetworkArrays matrix is array_equal, on every bundled fixture, with no tolerance. The bundle is a machine-facing, bit-exact spelling of the native schema, for spreadsheet tooling; it is not a second schema.

Function Does
csv_bundle.dump(net, directory) Write the manifest and every table (the directory is created). All-or-nothing: the files are rendered first and written into a fresh temporary sibling directory (.<name>.tmp-<random>); a directory that already holds a bundle is then swapped as a directory (renamed aside, the new one renamed in, the old one removed, foreign files carried over), so a failure — the "" refusal below, a full disk, a table another program holds open (Windows refuses the rename before anything moves) — leaves the previous bundle byte-for-byte untouched and nothing beside it. A directory without a bundle in it (the working directory, say) is filled in place; a directory that is a file is refused (NotADirectoryError) before anything is written.
csv_bundle.load(directory) -> Network Read and validate a bundle.
csv_bundle.load_with_report(directory) -> (Network, ImportReport) Same; the report is always empty on success, because there is nothing a bundle can repair.

Layout

manifest.json carries what is not tabular:

{"format": "mambo-power-csv", "schema_version": 1, "base_mva": 100.0,
 "tables": {"buses.csv": 14, "branches.csv": 20, "...": 0}}

schema_version is Network.schema_version — the native format's own version. The tables, in manifest order (csv_bundle.TABLES):

File Rows Columns
buses.csv one per Bus the model's field names verbatim and in field order; geo flattened to geo_lat, geo_lon
branches.csv one per Branch id, from_bus, to_bus, r, x, b, rating_mva, tap_ratio, shift_deg, in_service, kind
generators.csv one per Generator field names; cost flattened to cost_kind, cost_startup, cost_shutdown
generator_costs.csv one per coefficient or breakpoint generator_id, index, p_mw, value — polynomial: p_mw empty, value = coefficient, highest order first; piecewise: p_mw, value = cost; index is the 0-based position
loads.csv one per Load field names; bid flattened to bid_kind
load_bids.csv one per coefficient or breakpoint load_id, index, p_mw, value, same shape as the cost side table
shunts.csv, storage.csv, zones.csv one per entity field names

Long format for costs and bids was chosen over a JSON cell because a coefficient is then a cell and a breakpoint a row — the spreadsheet-friendly form.

Cell rules

  • Empty cell ⇔ None. Consequently an optional string field (Bus.area, Bus.zone, Zone.name) cannot carry "": dump raises ValueError rather than write a bundle that would read back differently. Required string fields (ids, bus references) round-trip "".
  • Ids and every other string are written and read as text; nothing is ever passed to int(), so "01" and "1" stay distinct.
  • Floats are written with repr (the shortest round-trip form) and read with float; nan / inf are rejected on read, as the model rejects them.
  • Booleans are written true / false; true / false / 1 / 0 are accepted on read in any case.
  • Empty tables are written header-only, so the manifest's table set never varies.
  • Row order is list order and is preserved. A fully blank row is skipped (an editor's trailing newline does not change the row count), and a UTF-8 BOM at the start of a table (Excel's "CSV UTF-8" save) is ignored; the writer emits plain UTF-8 with no BOM.

Errors

A bundle is either exact or refused. load_with_report validates the whole directory and collects every problem before giving up; the issues are raised as ReportError, whose .report.errors carry them (all as errors — nothing here is a repair). This is the other error surface of the wave: the RAW importer raises RawImportError at the first structural fault because nothing after it can be read, while a bundle's tables are independent, so every fault can be listed at once. Both are ValueErrors; only the CSV codes are ImportIssueCodes:

Code Cause
CSV_MANIFEST_INVALID manifest.json missing, not JSON, not format = "mambo-power-csv", base_mva not a finite number, tables not exactly the nine files, or a row count that disagrees with the file.
CSV_SCHEMA_VERSION schema_version is not the one this build reads.
CSV_MISSING_TABLE A listed file is absent.
CSV_UNKNOWN_COLUMN A header the model does not have.
CSV_MISSING_COLUMN A model field without a column.
CSV_DUPLICATE_ID The same id twice in one table.
CSV_BAD_VALUE A required cell empty, a cell that is not a float / boolean / finite, a row with the wrong number of cells, a cell longer than Python's csv field limit (131 072 characters — the whole table is then unreadable and reported once), or a per-entity validation failure (p_mw must be increasing, ...).
CSV_ORPHAN_ROW A generator_costs.csv / load_bids.csv row whose owner id is absent from its table.

Cross-entity invariants (dangling references, slack count, connectivity) are the model's own and raise NetworkValidationError, exactly as for the native format.

Limitations

  • The bundle carries what the native schema carries and nothing else; it does not accept extra columns (an editor's helper column is CSV_UNKNOWN_COLUMN).
  • An optional string field holding "" cannot be written (see the cell rules); the model treats "" and None as different values, and the bundle cannot.
  • Spreadsheet applications that reformat floats on save (0.10,1, 1e-050.00001) or coerce 01 to 1 break the bit-exact guarantee; the bundle detects the former as CSV_BAD_VALUE and cannot detect the latter.

Example

import tempfile
from pathlib import Path

from mambo_power.io import csv_bundle, matpower

net = matpower.load("fixtures/matpower/case14.m")
with tempfile.TemporaryDirectory() as directory:
    csv_bundle.dump(net, directory)
    print(sorted(p.name for p in Path(directory).iterdir()))
    print(Path(directory, "branches.csv").read_text().splitlines()[:2])
    print(csv_bundle.load(directory) == net)
['branches.csv', 'buses.csv', 'generator_costs.csv', 'generators.csv', 'load_bids.csv', 'loads.csv', 'manifest.json', 'shunts.csv', 'storage.csv', 'zones.csv']
['id,from_bus,to_bus,r,x,b,rating_mva,tap_ratio,shift_deg,in_service,kind', 'branch-1,bus-1,bus-2,0.01938,0.05917,0.0528,,,,true,line']
True

Bundled fixtures

The repository ships MATPOWER cases under fixtures/matpower/ with their provenance recorded in PROVENANCE.md / SOURCES.md: case14, case30, case_ieee30, case57, case118 and case300 (verbatim bytes with recorded sha256), plus derived variants under derived/ that exercise effective-role and island handling. These are public IEEE test data as distributed by MATPOWER; see the provenance files for the exact wording.